As everyone knows, the heavy load (w/m2) in computer applications is mainly caused by the increasing loads of data center racks and it finally produces heat load density which is relatively high. Because of unpredictable heavy loads, the remarkable performance of cooling system is required, at the same time occupies small space, so as provides more space for equipment in the room.
众所周知,机房应用中的负载负荷(w/m2)不断的上升,主要是由数据中心机架负荷的增加而造成,最终产生了比较高的热负荷密度。这要求空调系统具有更卓越的性能,同时尽可能占小的空间,从而为机房设备提供更大的空间。
Air-Blade has the advantage of energy saving in the market of air-conditioning because the space is the same as the value.
Air-Blade是市场上最具节能性的空调。 因为空间意味着价值。
Blade series is applicable for the server (horizontal blower type) with a surrounding air inlet and split system.It can meet the needs of a new generation of computer room and server center refrigeration standard. The refrigeration density for the blade series is very high (on the surface of 0.8mm2 reaches as high as 25KW). By using the modularized design including adaptive logic system can be managed through network, and the blade series is the best partner for the architecture of blade server and high density equipment. It is the ideal refrigeration system for the telephone, internet, data center, service center, and high density of buildings.
刀片风用在服务器上(水平送风式)有一款周围进气和风分体机系统,可满足新一代计算机房和服务器中心制冷标准。具有极高的制冷密度(在0.8mm2的表面上 高达25KW)。采用模坱化设计,包含自适应罗辑系统,可通过连网进行管理,是刀片服务器架构和高密度设备的最佳合作伙伴,是成为电话局、数据中心、互联 网、服务中心和高密度建筑物的理想制冷系统。
Characteristicfor Air-Blade (刀片风的特点):
Precision air inlet: Air volume can be controlled automatically according to the heat load and the needs of airflow;
精密送风:按需求送风,风量可根据热负荷自动控制;
Thenearest air inlet: The nearest air inlet and channelized closed system can achieve precise control of airflow;
就近送风:与信道封闭系统配合,使用可实现气流精密可控;
Fan with energy saving: The distance of wind blowing is short, the air circulation resistance is small, and the power consumption of the fan isless;
风机节能:送风距离短,送回风循环风阻小,风机功耗小;
Refrigeration system with energy saving: It can be matched with the channelized closed system, used to work at the high temperature environment, and is highly efficient and energy saving;
制冷系统节能:可与信道封闭系统配合,使用在高回风温度下工作,高效节能;
Installation easily: There is no need to install ventilation system under the ground. The cooling system is installed inside the cabinet which sucks out the rear or valve of the heat from the machine. The cold air is passed through the cooling channel and out in the front side of machine. The equipment is capable of absorbing heat from the cooling channel. The cooling facility is also applicable to update and upgrade under the existing structure of regulations.
安装简易:在地板下无需安装通气和通风系统。安装在机柜内便于冷却,从而吸出后部或阀通道的热气来自于机器,所谓的冷道从前侧放(冷却后),设备可从冷通道吸热气冷却,且也适用于更新和升级依据现有规定的结构。
This chart is for reference only, the new design of components and structures for the unit will change depending on the actual situation.
此工程图仅供参考,新机型所使用的元件及机组内部的设计会根据实际状况而有所变动。